ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
COSTCO D.97A

COSTCO — EDIFACT Container Stuffing Confirmation Message (D.97A)

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L. This page summarises the segment structure as published by UN/CEFACT for directory D.97A.

Purpose

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L.

This page focuses on the structure published by UN/CEFACT for directory D.97A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file costco_s.htm hosted on service.unece.org.

Segment structure

The COSTCO D.97A message has 50 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodC×9
0040FTXFree textC×9
0050  SG1Group (×9)C×9
0060  RFFReferenceM1
0070  DTMDate/time/periodC×9
0080    SG2Group (×1)M1
0090    TDTDetails of transportM1
0100    LOCPlace/location identificationC×9
0110    DTMDate/time/periodC×9
0120      SG3Group (×9)M×9
0130      NADName and addressM1
0140        SG4Group (×9)C×9
0150        CTAContact informationM1
0160        COMCommunication contactC×9
0170          SG5Group (×999)M×999
0180          EQDEquipment detailsM1
0190          RFFReferenceC×9
0200          DTMDate/time/periodC×9
0210          TSRTransport service requirementsC×9
0220          DIMDimensionsC×9
0230          SELSeal numberC×9
0240          EQAAttached equipmentC×9
0250          HANHandling instructionsC×9
0260          NADName and addressC×9
0270            SG6Group (×999)M×999
0280            CNIConsignment informationM1
0290            RFFReferenceC×9
0300              SG7Group (×999)C×999
0310              GIDGoods item detailsM1
0320              HANHandling instructionsC×9
0330              TMPTemperatureC×9
0340              RNGRange detailsC×9
0350              FTXFree textC×9
0360              MEAMeasurementsC×9
0370              PCIPackage identificationC×9
0380              DOCDocument/message detailsC×9
0390                SG8Group (×999)M×999
0400                SGPSplit goods placementM1
0410                MEAMeasurementsC×9
0420                  SG9Group (×9)C×9
0430                  DGSDangerous goodsM1
0440                  FTXFree textC×9
0450                  MEAMeasurementsC×9
0460                    SG10Group (×999)C×999
0470                    SGPSplit goods placementM1
0480                    MEAMeasurementsC×9
0490                    CNTControl totalC1
0500UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.97A for the COSTCO message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • COM in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.

Status changes (M ↔ C)

  • CTA (header): status C in D.96A → M in D.97A.
  • CNT (header): status M in D.96A → C in D.97A.

Max-repeat changes

  • RFF (header): repeat ×9 in D.96A → ×1 in D.97A.
  • CTA (header): repeat ×9 in D.96A → ×1 in D.97A.

Structural example

Minimal example of an COSTCO D.97A message with mandatory segments only. The goal is to show the exact version declared in UNH (COSTCO:D:97A:UN) — not to replicate a full business case (see the COSTCO D.96A page for an annotated example).

edifact costco-d97a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL097001'
UNH+1+COSTCO:D:97A:UN'
BGM+267+COSTCO-2026-0152+9'
DTM+137:202605141430:203'
DTM+138:202605141200:203'
FTX+AAI+++Stuffing completed - high cube container - 24 pallets'
UNT+6+1'
UNZ+1+CTRL097001'

Common errors

  • Misaligned UNH tokens — The UNH+...+COSTCO:D:97A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.97A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: COSTCO D.96A, COSTCO D.01B, COSTCO D.10A, COSTCO D.16B, COSTCO D.21B, COSTCO D.24A, COSTCO D.99B, COSTCO D.00B, COSTCO D.02B, COSTCO D.05A, COSTCO D.08A, COSTCO D.13B, COSTCO D.18B, COSTCO D.20B.

← All EDIFACT versions