ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
COSTCO D.10A

COSTCO — EDIFACT Container Stuffing Confirmation Message (D.10A)

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L. This page summarises the segment structure as published by UN/CEFACT for directory D.10A.

Purpose

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L.

This page focuses on the structure published by UN/CEFACT for directory D.10A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file costco_c.htm hosted on service.unece.org.

Segment structure

The COSTCO D.10A message has 67 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodC×9
0040FTXFree textC×9
0050  SG1Group (×9)C×9
0060  RFFReferenceM1
0070  DTMDate/time/periodC×9
0080    SG2Group (×1)M1
0090    TDTTransport informationM1
0100    DTMDate/time/periodC×9
0110    RFFReferenceC×9
0120      SG3Group (×9)C×9
0130      LOCPlace/location identificationM1
0140      DTMDate/time/periodC×9
0150        SG4Group (×9)M×9
0160        NADName and addressM1
0170          SG5Group (×9)C×9
0180          CTAContact informationM1
0190          COMCommunication contactC×9
0200            SG6Group (×999)M×999
0210            EQDEquipment detailsM1
0220            RFFReferenceC×9
0230            DTMDate/time/periodC×9
0240            TSRTransport service requirementsC×9
0250            DIMDimensionsC×9
0260            SELSeal numberC×9
0270            EQAAttached equipmentC×9
0280            HANHandling instructionsC×9
0290            NADName and addressC×9
0300              SG7Group (×99)C×99
0310              DGSDangerous goodsM1
0320              FTXFree textC×9
0330              MEAMeasurementsC×9
0340                SG8Group (×9)C×9
0350                CTAContact informationM1
0360                COMCommunication contactC×9
0370                  SG9Group (×9)C×9
0380                  TMPTemperatureM1
0390                  RNGRange detailsC1
0400                    SG10Group (×999)M×999
0410                    CNIConsignment informationM1
0420                    RFFReferenceC×9
0430                      SG11Group (×999)C×999
0440                      GIDGoods item detailsM1
0450                      HANHandling instructionsC×9
0460                        SG12Group (×9)C×9
0470                        TMPTemperatureM1
0480                        RNGRange detailsC1
0490                        FTXFree textC×9
0500                        MEAMeasurementsC×9
0510                        PCIPackage identificationC×9
0520                        DOCDocument/message detailsC×9
0530                          SG13Group (×999)M×999
0540                          SGPSplit goods placementM1
0550                          MEAMeasurementsC×9
0560                            SG14Group (×99)C×99
0570                            DGSDangerous goodsM1
0580                            FTXFree textC×9
0590                            MEAMeasurementsC×9
0600                              SG15Group (×9)C×9
0610                              CTAContact informationM1
0620                              COMCommunication contactC×9
0630                                SG16Group (×999)C×999
0640                                SGPSplit goods placementM1
0650                                MEAMeasurementsC×9
0660                                CNTControl totalC1
0670UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.10A for the COSTCO message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • COM in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.

Status changes (M ↔ C)

  • LOC (header): status C in D.96A → M in D.10A.
  • CTA (header): status C in D.96A → M in D.10A.
  • TMP (header): status C in D.96A → M in D.10A.
  • CNT (header): status M in D.96A → C in D.10A.

Max-repeat changes

  • RFF (header): repeat ×9 in D.96A → ×1 in D.10A.
  • LOC (header): repeat ×9 in D.96A → ×1 in D.10A.
  • CTA (header): repeat ×9 in D.96A → ×1 in D.10A.
  • TMP (header): repeat ×9 in D.96A → ×1 in D.10A.
  • RNG (header): repeat ×9 in D.96A → ×1 in D.10A.

Structural example

Minimal example of an COSTCO D.10A message with mandatory segments only. The goal is to show the exact version declared in UNH (COSTCO:D:10A:UN) — not to replicate a full business case (see the COSTCO D.96A page for an annotated example).

edifact costco-d10a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL010001'
UNH+1+COSTCO:D:10A:UN'
BGM+267+COSTCO-2026-0152+9'
DTM+137:202605141430:203'
DTM+138:202605141200:203'
FTX+AAI+++Stuffing completed - high cube container - 24 pallets'
UNT+6+1'
UNZ+1+CTRL010001'

Common errors

  • Misaligned UNH tokens — The UNH+...+COSTCO:D:10A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.10A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: COSTCO D.96A, COSTCO D.16B, COSTCO D.21B, COSTCO D.24A.

← All EDIFACT versions