COSTCO D.96A

COSTCO — EDIFACT Container Stuffing Confirmation Message (D.96A)

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L. This page summarises the segment structure as published by UN/CEFACT for directory D.96A.

Purpose

The COSTCO message confirms the stuffing (loading) of a container, sent by a container depot operator or a consolidator: it fixes the actual contents (commodities, weight, seals), stuffing date and references to the upcoming booking and B/L.

This page focuses on the structure published by UN/CEFACT for directory D.96A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file costco_s.htm hosted on service.unece.org.

Segment structure

The COSTCO D.96A message has 44 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030FTXFree textC×9
0040RFFReferenceM×9
0050  SG1Group (×1)M1
0060  TDTDetails of transportM1
0070  LOCPlace/location identificationC×9
0080  DTMDate/time/periodC×9
0090    SG2Group (×9)M×9
0100    NADName and addressM1
0110    CTAContact informationC×9
0120      SG3Group (×999)M×999
0130      EQDEquipment detailsM1
0140      RFFReferenceC×9
0150      DTMDate/time/periodC×9
0160      TSRTransport service requirementsC×9
0170      DIMDimensionsC×9
0180      SELSeal numberC×9
0190      EQAAttached equipmentC×9
0200      NADName and addressC×9
0210        SG4Group (×999)M×999
0220        CNIConsignment informationM1
0230        RFFReferenceC×9
0240          SG5Group (×999)C×999
0250          GIDGoods item detailsM1
0260          HANHandling instructionsC×9
0270          TMPTemperatureC×9
0280          RNGRange detailsC×9
0290          FTXFree textC×9
0300          MEAMeasurementsC×9
0310          PCIPackage identificationC×9
0320          DOCDocument/message detailsC×9
0330            SG6Group (×999)M×999
0340            SGPSplit goods placementM1
0350            MEAMeasurementsC×9
0360              SG7Group (×9)C×9
0370              DGSDangerous goodsM1
0380              FTXFree textC×9
0390              MEAMeasurementsC×9
0400                SG8Group (×999)C×999
0410                SGPSplit goods placementM1
0420                MEAMeasurementsC×9
0430                CNTControl totalM1
0440UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

This page documents directory D.96A itself: it serves as the reference for every other version of the message. The synthesis below describes the structural changes that later directories will introduce relative to it.

No top-level differences detected between D.96A and D.96A for this message. Differences are then limited to nested groups and code lists.

Structural example

Minimal example of an COSTCO D.96A message with mandatory segments only. The goal is to show the exact version declared in UNH (COSTCO:D:96A:UN) — not to replicate a full business case.

edifact costco-d96a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL096001'
UNH+1+COSTCO:D:96A:UN'
BGM+267+COSTCO-2026-0152+9'
DTM+137:202605141430:203'
DTM+138:202605141200:203'
FTX+AAI+++Stuffing completed - high cube container - 24 pallets'
UNT+6+1'
UNZ+1+CTRL096001'

Common errors

  • Misaligned UNH tokens — The UNH+...+COSTCO:D:96A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.96A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: COSTCO D.10A, COSTCO D.16B, COSTCO D.21B, COSTCO D.24A.

← All EDIFACT versions