ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
MOVINS D.13B

MOVINS — EDIFACT Stowage Instruction Message (D.13B)

The MOVINS message conveys container loading and discharge instructions sent by a carrier to a port terminal: which containers to load, discharge or re-stow on which vessel, at which position and under which constraints. This page summarises the segment structure as published by UN/CEFACT for directory D.13B.

Purpose

The MOVINS message conveys container loading and discharge instructions sent by a carrier to a port terminal: which containers to load, discharge or re-stow on which vessel, at which position and under which constraints.

This page focuses on the structure published by UN/CEFACT for directory D.13B. The segments listed, their status (M / C), position and repetition factor are extracted from the official file movins_c.htm hosted on service.unece.org.

Segment structure

The MOVINS D.13B message has 45 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
00010UNHMessage headerM1
00020BGMBeginning of messageM1
00030DTMDate/time/periodM1
00040  SG1Group (×9)C×9
00050  RFFReferenceM1
00060  DTMDate/time/periodC×9
00070    SG2Group (×9)C×9
00080    NADName and addressM1
00090      SG3Group (×9)C×9
00100      CTAContact informationM1
00110      COMCommunication contactC×9
00120        SG4Group (×3)M×3
00130        TDTTransport informationM1
00140        LOCPlace/location identificationM1
00150        DTMDate/time/periodM×99
00160        RFFReferenceC1
00170        FTXFree textC1
00180          SG5Group (×99999)C×99999
00190          HANHandling instructionsM1
00200            SG6Group (×99999)C×99999
00210            LOCPlace/location identificationM1
00220            RFFReferenceM×99
00230            FTXFree textC×9
00240            MEAMeasurementsC×9
00250            DIMDimensionsC×9
00260            LOCPlace/location identificationC×9
00270            NADName and addressM×99
00280              SG7Group (×1)C1
00290              TMPTemperatureM1
00300              RNGRange detailsC1
00310                SG8Group (×99)C×99
00320                EQDEquipment detailsM1
00330                EQNNumber of unitsC1
00340                  SG9Group (×99)C×99
00350                  EQAAttached equipmentM1
00360                  EQNNumber of unitsC1
00370                    SG10Group (×9999)C×9999
00380                    GIDGoods item detailsM1
00390                    GDSNature of cargoC1
00400                      SG11Group (×999)C×999
00410                      RFFReferenceM1
00420                        SG12Group (×99)M×99
00430                        DGSDangerous goodsM1
00440                        FTXFree textC1
00450UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.13B for the MOVINS message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • CTA in the header section (status M, repeat ×1) — not present at the top of the corresponding D.96A section.
  • COM in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.

Status changes (M ↔ C)

  • NAD (header): status C in D.96A → M in D.13B.

Max-repeat changes

  • NAD (header): repeat ×3 in D.96A → ×1 in D.13B.

Structural example

Minimal example of an MOVINS D.13B message with mandatory segments only. The goal is to show the exact version declared in UNH (MOVINS:D:13B:UN) — not to replicate a full business case (see the MOVINS D.96A page for an annotated example).

edifact movins-d13b-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL013001'
UNH+1+MOVINS:D:13B:UN'
BGM+244+MOVINS-2026-0188+9'
DTM+137:202605141430:203'
TDT+20+MSC1234W+1++MSC::ZZZ+++9301234:103:::MSC OSCAR'
LOC+11+FRLEH::6'
LOC+13+NLRTM::6'
EQD+CN+MSCU1234567+45G1+++5'
HAN+L'
LOC+147+0010186::ZZZ'
UNT+9+1'
UNZ+1+CTRL013001'

Common errors

  • Misaligned UNH tokens — The UNH+...+MOVINS:D:13B:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.13B, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: MOVINS D.96A, MOVINS D.01B, MOVINS D.10A, MOVINS D.16B, MOVINS D.21B, MOVINS D.24A, MOVINS D.97A, MOVINS D.99B, MOVINS D.00B, MOVINS D.02B, MOVINS D.05A, MOVINS D.08A, MOVINS D.18B, MOVINS D.20B.

← All EDIFACT versions