INSREQ D.08A

INSREQ — EDIFACT Inspection Request Message (D.08A)

The INSREQ message is the inspection request sent to a control body or service provider: it specifies what to inspect, where, when, against which standard, and with which urgency — quality, regulatory compliance, customs, veterinary. This page summarises the segment structure as published by UN/CEFACT for directory D.08A.

Purpose

The INSREQ message is the inspection request sent to a control body or service provider: it specifies what to inspect, where, when, against which standard, and with which urgency — quality, regulatory compliance, customs, veterinary.

This page focuses on the structure published by UN/CEFACT for directory D.08A. The segments listed, their status (M / C), position and repetition factor are extracted from the official file insreq_c.htm hosted on service.unece.org.

Segment structure

The INSREQ D.08A message has 38 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodM×99
0040  SG1Group (×99)C×99
0050  RFFReferenceM1
0060  DTMDate/time/periodC×9
0070    SG2Group (×99)M×99
0080    NADName and addressM1
0090    LOCPlace/location identificationC×99
0100      SG3Group (×99)M×99
0110      DOCDocument/message detailsM1
0120        SG4Group (×99)C×99
0130        RFFReferenceM1
0140        DTMDate/time/periodC×99
0150          SG5Group (×99)C×99
0160          NADName and addressM1
0170            SG6Group (×99)C×99
0180            CTAContact informationM1
0190            COMCommunication contactC×99
0200              SG7Group (×999)C×999
0210              LINLine itemM1
0220              PIAAdditional product idC×99
0230              IMDItem descriptionC×99
0240              DTMDate/time/periodC×99
0250              RFFReferenceC×99
0260              FTXFree textC×9
0270                SG8Group (×999)C×999
0280                NADName and addressM1
0290                GEIProcessing informationC×99
0300                LOCPlace/location identificationC×99
0310                QTYQuantityC×99
0320                QVRQuantity variancesC×99
0330                RFFReferenceC×99
0340                FTXFree textC×9
0350                  SG9Group (×999)C×999
0360                  GINGoods identity numberM1
0370                  RFFReferenceC×99
0380UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

The INSREQ message is not published in directory D.96A. No "D.96A → D.08A" comparison line can therefore be produced — see the block below for details.

This message is not published in directory D.96A: it was introduced into the standard after that release and therefore has no historical baseline for comparison. The first directory indexed on ediverse.io sets the reference; later changes are then documented from one release to the next in subsequent directories.

Structural example

Minimal example of an INSREQ D.08A message with mandatory segments only. The goal is to show the exact version declared in UNH (INSREQ:D:08A:UN) — not to replicate a full business case.

edifact insreq-d08a-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL008001'
UNH+1+INSREQ:D:08A:UN'
BGM+701+INSREQ-2026-0220+9'
DTM+137:20260514:102'
DTM+200:20260520:102'
NAD+ON+5410000000123::9'
NAD+IS+5410000000456::9'
LOC+18+FRLEH::6'
LIN+1++3520000001234:EN'
QTY+1:500'
FTX+AAI+++Quality inspection on receipt - ISO 9001'
UNT+10+1'
UNZ+1+CTRL008001'

Common errors

  • Misaligned UNH tokens — The UNH+...+INSREQ:D:08A:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.08A, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: INSREQ D.01B, INSREQ D.10A, INSREQ D.16B, INSREQ D.21B, INSREQ D.24A, INSREQ D.99B, INSREQ D.00B, INSREQ D.02B, INSREQ D.05A, INSREQ D.13B, INSREQ D.18B, INSREQ D.20B.

X12 functional equivalent: X12 142.