ediverse Explore the platform

Spotlight PEPPOL BIS Billing 3.0 The EU e-invoicing mandate is here — France Sept 2026, Belgium Jan 2026, Germany 2025.
BAPLTE D.99B

BAPLTE — EDIFACT Bayplan / Stowage Plan Total Numbers Message (D.99B)

The BAPLTE message is the aggregated complement to BAPLIE: rather than listing every container, it conveys totals per cell, per weight category and per package type on board a vessel. It progressively faded after D.02B in favour of BAPLIE alone, but remains indexed in the earlier directories. This page summarises the segment structure as published by UN/CEFACT for directory D.99B.

Purpose

The BAPLTE message is the aggregated complement to BAPLIE: rather than listing every container, it conveys totals per cell, per weight category and per package type on board a vessel. It progressively faded after D.02B in favour of BAPLIE alone, but remains indexed in the earlier directories.

This page focuses on the structure published by UN/CEFACT for directory D.99B. The segments listed, their status (M / C), position and repetition factor are extracted from the official file baplte_c.htm hosted on service.unece.org.

Segment structure

The BAPLTE D.99B message has 25 header entries, 0 detail entries and 0 summary entries (segments and groups combined). Groups are shown in bold and their members are indented by actual nesting depth.

Pos.TagNameSRep.
0010UNHMessage headerM1
0020BGMBeginning of messageM1
0030DTMDate/time/periodM1
0040  SG1Group (×9)C×9
0050  RFFReferenceM1
0060  DTMDate/time/periodC×9
0070    SG2Group (×9)C×9
0080    NADName and addressM1
0090      SG3Group (×9)C×9
0100      CTAContact informationM1
0110      COMCommunication contactC×9
0120        SG4Group (×3)M×3
0130        TDTDetails of transportM1
0140        LOCPlace/location identificationM×2
0150        DTMDate/time/periodM×99
0160        RFFReferenceC1
0170        FTXFree textC1
0180          SG5Group (×999)C×999
0190          LOCPlace/location identificationM1
0200          GIDGoods item detailsC1
0210            SG6Group (×9999)C×9999
0220            EQDEquipment detailsM1
0230            EQNNumber of unitsC1
0240            RFFReferenceC×9
0250UNTMessage trailerM1

Detail

No segment in this section.

Summary

No segment in this section.

Changes vs D.96A

Top-level differences between D.96A and D.99B for the BAPLTE message (segments directly inside header / detail / summary, ignoring nested groups). The comparison is indicative: a given tag may have evolved inside nested groups without showing up in this synthesis.

Segments added vs D.96A

  • CTA in the header section (status M, repeat ×1) — not present at the top of the corresponding D.96A section.
  • COM in the header section (status C, repeat ×9) — not present at the top of the corresponding D.96A section.

Status changes (M ↔ C)

  • NAD (header): status C in D.96A → M in D.99B.

Max-repeat changes

  • NAD (header): repeat ×3 in D.96A → ×1 in D.99B.

Structural example

Minimal example of an BAPLTE D.99B message with mandatory segments only. The goal is to show the exact version declared in UNH (BAPLTE:D:99B:UN) — not to replicate a full business case (see the BAPLTE D.96A page for an annotated example).

edifact baplte-d99b-example.edi
UNB+UNOC:3+5410000000123:14+5410000000456:14+260514:1430+CTRL099001'
UNH+1+BAPLTE:D:99B:UN'
BGM+244+BAPLTE-2026-MSC1234+9'
DTM+137:202605141430:203'
TDT+20+MSC1234W+1++MSC::ZZZ+++9301234:103:::MSC OSCAR'
LOC+5+FRLEH::6'
LOC+147+0010186::ZZZ'
EQA+TC+45G1'
CNT+16:48'
MEA+AAE+G+KGM:1176000'
UNT+9+1'
UNZ+1+CTRL099001'

Common errors

  • Misaligned UNH tokens — The UNH+...+BAPLTE:D:99B:UN token must reflect exactly the directory in use — a mismatch between the UNH release and the release agreed with the partner is rejected by every strict validator.
  • Wrong UNT segment count — The value after UNT+ must include UNH and UNT themselves. By far the most common sender-side error, regardless of the directory in use.
  • Stale code lists — Between D.96A and D.99B, several code lists received new qualifiers (DTM status, RFF qualifier, NAD codes…). Reusing an older directory’s code tables triggers warnings or even rejections depending on the partner’s strict-conformance mode.

Other versions of this message available on ediverse.io: BAPLTE D.96A, BAPLTE D.01B, BAPLTE D.97A, BAPLTE D.00B, BAPLTE D.02B.

← All EDIFACT versions