MSA

HL7 v2 segment, acknowledgments and flow control.

Definition

MSA-1 holds the acknowledgment code (HL7 table 0008): AA (Application Accept), AE (Application Error) or AR (Application Reject) in original mode, and CA/CE/CR in enhanced mode. MSA-2 echoes the Message Control ID (MSH-10) of the acknowledged message to correlate the response with the original request.

Origin

Defined in Chapter 2 (Control) of the HL7 Version 2.x Messaging Standard, published by Health Level Seven International (HL7).

Example in context

MSH|^~\&|...|ACK|MSG99001|P|2.5.1\nMSA|AA|MSG00001